Tisch: TE-6070
High Volume PM10 Mass Flow controlled (MFC) Monitor
in Ambient Air
Complete
with Size selective inlet, outdoor anodized aluminum shelter, aluminum blower
motor assembly, 8" x 10" stainless steel filter holder, mass flow
controller with 20/60 scfm flow probe,7-day mechanical timer, elapsed time
indicator, continuous flow/pressure recorder, and filter paper cartridge
(110v/60hz or 220v/50hz)
|
Specifications |
|
|
Inlet
collection efficiency: |
Meets
EPA’s PM-10 Code of Federal Regulations Appendix J to Part 50 |
|
Flow
rate: |
40
cfm (adjustable) (1.02 to 1.24m³) |
|
Filter
media: |
Micro-Quartz
filter media 8" x 10" for PM10 (TE-QMA) |
|
Flow
control: |
MFC (TE-300-310) |
|
Motor
blower: |
2-stage vacuum 0.6 HP
110v/60hz (TE-116311), 220v/50hz (TE-116312) |
|
Flow
Indicator: |
Flow/pressure recorder
(TE-5009) with TE-106 Charts |
|
Mechanical
programmable timer |
7-day mechanical timer
(TE-5007) |
|
Elapsed
time indicator device: |
Elapsed
Time Indicator (TE-5012) |
|
Sample
Module: |
Particulate/vapor
sampling module with Tischaloy coating (TE-1002) |
|
Shipping Information |
|
|
Size: |
22.5"
x 20" x 45.5" sampler carton, 32" x 32" x 25.5"
inlet carton |
|
Weight: |
65
lbs. – sampler carton, 60 lbs. - inlet carton |
|
Assembled
Space Requirement: |
30"
round x 64" high |
|
Power
Requirement |
Single
phase with earth ground, 110v/60hz
or 220v/50hz |
|
Motor
Specifications: |
110v/60hz
– Part #TE-116311, 2-stage vacuum 0.6 HP, double ball bearing thru-flow
discharge, 220v/50hz
– Part #TE-116312, 2-stage vacuum 0.6 HP,ball/sleeve bearing thru-flow
discharge |
|
Altitude
Application: |
to 10,000
feet above sea level |
|
Ambient
Temperature Application: |
-30 to +
50ºC |
|
Relative
Humidity Application: |
0 - 100% |
|
Sample Delay Start Range: |
0 - 7 days |
|
Start up
amps: |
12 amps |
|
Running
amps: |
4 amps |