Enerac 2000
| Physical: | 1. Case: 18" x 13" x
6" Aluminum case with lock. Weight: 15 lbs
2. Probe: 13"L x 3/8" OD. Inconel probe with aluminum handle and 10' hose std. (Other sizes optional). |
| Electrical: | 1. Battery: 6V. rechargeable
cell. 4 hour continuous operation on batteries. Quick 4 hour recharge.
2. AC: 120V. 60 Hz. std. (220V. 50 Hz. optional) 1A |
| Display | 0.5" High by 25 Character single line LCD with backlight illumination and adjustable viewing angle. |
| Printer: |
4" wide. 40 char. per line thermal printer with form feed and line feed buttons and end of paper override. Operates in any three modes: 1. Text Mode:25 line printout of current values of all measured parameters (time req 20 sec). 2. Plot Mode: Any one parameter vs. time plotted , 3 ordinate scales: full, half, quarter. Time scale: Selectable, 1 sec/dot-1 min/dot in 1 sec/dot intervals. 3. External Print Mode: Prints messages sent via RS-232 port or modem. |
| Storage: | Internal: 99 individually selectable buffers hold one complete set of measurements each, including boiler identification number, in non volatile memory. Buffer contents can be sent to printer, RS-232 port or modem. |
| Micro-Computer: | Accessory micro-computer can store up to 300 measurements in non volatile memory. |
| Communications |
1.RS-232 Port. 1200 baud, 1 start bit, 8 bits, 1 stop bit, no parity. 2. Modem: Internal 1200 baud auto-answer modem connects to any modular phone line for remote cummunication. (A 50 word command set sends instructions to the unit for remote control and troubleshooting) |
| Miscellaneous: |
1. Fuels: 15 fuels, 3 in foreground, 12 in background standard. Custom fuels available on request. 2. CO alarm: Selectable 0-2000 PPM in 10 PPM steps. 3. Combustibles in ash: Presettable 0-100% in 5% steps. 4. Messages: One hundred diagnostic and help messages. 5. Calibration: Autozero on start up, software span calibration CO, NOX, SO2, combustibles and draft. |