Enerac 2000E
| Physical |
1. CASE: 18"x13"x6" black anodized aluminum carrying case with lock. Weight 18 lbs. 2. PROBE: 24"L x 3/8" OD. Inconel probe with Hastelloy x sintered filter and 1/2" deflector mounted on permeation drier housing. Probe Housing connects to instrument via a 10 ft viton hose. (Other probe and hose sizes available) 3. PROBE: 13" L x 3/8" OD. Inconel probe with aluminum handle and 10' viton hose and watertrap. Max continuous temperature: 1800°F. Max. sample dew point (past drier) 50°F @ 600 cc/min (natural gas fuel) |
| Electrical Power: | 1. BATTERY: 6V
rechargeable sealed lead-acid cell. 5-hour continuous battery
operation. Quick 6-hour recharge.
2. AC: 120V, 60 Hz standard (220V, 50Hz, optional) |
| Display: | 0.5" high x 24 character single line LCD with backlight illumination and adjustable viewing angle. |
| Printer: | Seiko 4": 40 char/line
thermal printer with form feed and line feed buttons and with end of paper
override. Operates in any three modes. 1. Text Mode: 25 line printout of instant values of all measured parameters. (time req. 20 sec) 2. Plot Mode: Any one parameter vs time plotted. 3 ordinate scales: full, half, quarter. Time scale: Selectable, 1 sec/dot-1 min/dot in 1 sec/dot intervals. 4 parameter plot CO-OXYGEN-NOxEFFICIENCY, single scale. 3. External Print Mode: Prints messages sent via rs-232 port. |
| Storage | Internal: 99 individually selectable buffers hold one complete set of measurements each, including boiler identification number, in non volatile memory. Buffer contents can be sent to printer, RS-232 port or modem. |
| Communications | 1. RS-232 PORT: RS-232C port (DTE),
2400 baud, half duplex, 1 start bit, 8 data bits , 1 stop bits, no parity
2. Telephone Port: Internal 1200 baud modem connects to a modular phone line for remote communication. (A 50 word command set sends instructions to the unit for remote control and troubleshooting) 3. Software: Enercom Windows application software displays all parameters simultaneously, calculates min, max and average concentration, standard deviations, emissions calculations, plots line and bar graphs. Prints and saves data in a variety of common formats. |
| Miscellaneous | 1. Fuels: 15 fuels, 3 in
foreground, 12 in background standard. Custom fuels available on
request.
2. CO ALARM: Selectable 0-20000 PPM in 10 PPM 3. Combustibles in ash: presettable 0-100% in 5% steps. 4. Messages: 100 diagnostic and help messages 5. Calibration: Optional autozero on startup software span calibration CO, NO, NO2, SO2, combustibles. |